Flange isolation · dissimilar metals · bolted thermal breaks
An insulated joint is only as good as its bolts. If a bolt touches both sides, heat and current go straight through it. Micarta insulating washers and sleeves stop that: the sleeve lines the bolt hole and the washer sits under the nut, so nothing metal bridges the joint.
We machine washers, sleeves and shoulder bushings from STB-1 glass-epoxy laminate to suit your bolt size and grip. It takes 48,000 psi in compression under the nut and has a dielectric strength of 500 VPM.
Washers and sleeves for insulated flanges that separate cathodically protected piping from the rest of the system.
Break the electrical path where aluminum, stainless and carbon steel are bolted together, to prevent galvanic corrosion.
Pair washers and sleeves with a thermal break pad so the bolts do not undo the isolation the pad provides.
Isolate switchgear, bus supports and instrument mounts from structural steel and ground.
Insulate the bolts that hold a pipe support block to the rack on hot or cold lines.
The laminate is rated to −270 °C (−454 °F), so the same washers work on refrigeration and cryogenic connections.
| Property | Test method | Value |
|---|---|---|
| Compressive strength | ASTM D695 | 48,000 psi (330.9 MPa) |
| Shear strength | ASTM D732 | 16,326 psi |
| Dielectric strength, short time in oil, 1/16″ | ASTM D149 | 500 VPM |
| Arc resistance | ASTM D495 | 150 s |
| Dielectric constant @ 60 Hz | ASTM D150 | 4.8 |
| Water absorption | ASTM D229 | 0.35 % |
| Thermal conductivity | ASTM C518 | 1.055 BTU·in/hr·ft²·°F |
| Service temperature | — | −270 °C to 135 °C (−454 °F to 275 °F) |
Nominal values tested at room temperature.
Send your bolt sizes and drawings to sales@bmssi.ca or call 800-580-4195. We machine every washer and sleeve in house.